SP041 K-Series Distribution Terminal Blocks
K207, K211, K215, K407, K411 and K415 distribution terminal blocks. The catalogue lists 125 A and 500 V with model-specific body dimensions.
| Catalogue model / configuration | SP041/K207, SP041/K211, SP041/K215, SP041/K407, SP041/K411, SP041/K415 |
|---|
| Material | PC / PA |
|---|
| Contact material | Brass |
|---|
| Screw material | Zinc-plated steel |
|---|
| Connection / fixing | Screw connection |
|---|
Rigid and flexible conductor capacities differ by connection point. Request the exact port layout and conductor table for the selected K model.
Models and dimensions
Open a model or configuration to view its specifications. Dimensions follow the catalogue drawing labels; compare the matching drawing before assembly. Packing figures are catalogue references and should be confirmed with the quotation.
SP041/K207
| Item No. | SP041/K207 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 66 |
|---|
| H / mm | 45 |
|---|
| W / mm | 51 |
|---|
| PCS/CTN | 200 |
|---|
SP041/K211
| Item No. | SP041/K211 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 100 |
|---|
| H / mm | 45 |
|---|
| W / mm | 51 |
|---|
| PCS/CTN | 100 |
|---|
SP041/K215
| Item No. | SP041/K215 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 133 |
|---|
| H / mm | 45 |
|---|
| W / mm | 51 |
|---|
| PCS/CTN | 100 |
|---|
SP041/K407
| Item No. | SP041/K407 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 66 |
|---|
| H / mm | 88 |
|---|
| W / mm | 50 |
|---|
| PCS/CTN | 100 |
|---|
SP041/K411
| Item No. | SP041/K411 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 100 |
|---|
| H / mm | 88 |
|---|
| W / mm | 51 |
|---|
| PCS/CTN | 50 |
|---|
SP041/K415
| Item No. | SP041/K415 |
|---|
| CURRENT | 125A |
|---|
| VOLTAGE | 500V |
|---|
| WIRE RANGE / FLEXIBLE | Confirm connection-point drawing |
|---|
| WIRE RANGE / RIGID | Confirm connection-point drawing |
|---|
| L / mm | 133 |
|---|
| H / mm | 88 |
|---|
| W / mm | 51 |
|---|
| PCS/CTN | 50 |
|---|
Selection and quotation
Specify the exact model, conductor sizes, connection arrangement, required ratings, mounting dimensions and quantity. Include any drawing, material grade or compliance documents required for your project. Ratings apply to the listed model and configuration; installation details and order-specific requirements must be confirmed before use.
Specification reference: Antong product catalogue, PDF page 30. Optional materials and modified configurations require separate confirmation.